Product description:
DSC is a differential with the highest precision introduced by the company. The sensor adopts imported material sensor with high sensitivity. Signal acquisition circuit shielding protection, strong anti-interference, high baseline stability.
Differential scanning calorimeter is a touch screen type, which can perform glass transition temperature test, phase transition test, melting and enthalpy value test, product stability, curing, oxidation induction period test, and specific heat test. Wide range of applications
Technical parameter:
1. Temperature range: room temperature~1500℃
2. Temperature resolution: 0.001℃
3. Temperature fluctuation: ±0.001℃
4. Temperature repeatability: ±0.1℃
5. Heating rate: 0.1~80℃/min
6. Constant temperature time: program setting
7. Temperature control method: PID temperature control, heating, constant temperature (automatic program control)
8. DSC range: 0~±600mW
9.DSC resolution: 0.01uW
10. DSC sensitivity: 0.001mW
11. Working power supply: AC220V/50Hz or customized
12. Atmosphere control gas: nitrogen, oxygen (automatic switching of the instrument)
13. Gas flow: 0-300mL/min
14. Gas pressure: 0.2MPa
15. Display mode: 24bit color, 7-inch LCD touch screen display
16. Data interface: standard USB interface
17. Parameter standard: equipped with standard material (indium, tin), the user can calibrate the temperature by himself
18. The instrument has multiple sets of thermocouples, one set to test the sample temperature, and one set to test the internal ambient temperature of the instrument
19. The instrument has a multi-point calibration function, which can meet the precise test of high, medium and low samples
20. The software can set the frequency of data collection, and can export EXECL data packages and PDF reports
21. Curve scanning: heating scanning, cooling scanning, constant temperature scanning
Technical Features:
1. Industrial-grade 7-inch touch screen with rich display information.
2. The new ceramic furnace body structure has better baseline and higher precision. The heating adopts indirect conduction, which has high uniformity and stability, and reduces pulse radiation, which is superior to the traditional heating mode.
3. USB communication interface, strong versatility, reliable and uninterrupted communication, and supports self-recovery connection function.
4. Automatically switch the two-way atmosphere flow, the switching speed is fast, and the stabilization time is short. At the same time, a protective gas input is added.
5. The software is simple and easy to operate