Do we have to supply air compressor , and dust recovery?

If you use LDY2005B Wet Laser Particle Size Analyzers, it don't need air compressor and dust recovery.

If you use LDY 3005 Intelligent full automatic Laser Diffraction Particle Size Analyzer, we will equip with air compressor and dust recovery for you.

 

Will the test result be like Malvern ?

The test result is close to Malvern, you can send the sample to us, we will print the test report for you for free.

 

Can we connect a computer with windows 7 or 10? Usb cable?

Yes, you can connect with your computer. windows 7 is ok. We will send The cable with instrument and computer for you for free.

 

Please specify which reports we can get

The report index ,could analyze any parameter between D10 to D100.

 We can analyze any parameter which Malvern can test.

 

Can we get info on surface area of the sample?

Yes ,you can get info on surface area, which is indicated by S/V.

 

Is feeder included for dry testing ? If yes can it be regulated ?

If you use LDY3005 dry method  Particle Size Analyzer, the feeder is included. Yes, it can be regulated.

It can display the amount of test sample with CVT button and Concentration  histogram.

 

Does the software ensure that the detector scans where obscuration is outside target range by feeding ?

Yes, it can ensure. detectors are fab-shaped arrangement, it can select all the angles scattering light signals of particles .

 

Do you use Mie scattern theory ?

Yes, We use Mie scattern theory . And all our laser particle size analyzer use  MIE scattering principle.

 

Time for making 1 test ?

Our LDY2005B wet dispersion laser particle size analyzer test time is <2 mins.

 

Laser brand name ?

Our LDY2005B use HeNe laser , it is from Shanghai city good supplier

 

Expected life time for the laser

Expected life time is >25000 hours.

Our instrument life time could be 10-15 years at least.

For type 2001 :

Do you use He-Ne laser ?

Can you show me which reports we can get ?

Can it measure surface area of the particles ?

 

Upon your request, please kindly check the followings.

 

1. The fluctuation that the wavelength change 3 nanometers per 5 degree ,  is the characteristic of semiconductor lasers, and this fluctuation  has no effect on the test results.

 

2.Generally,if the instrument is cablirated firstly, and the instrument don't move, the

optical path don't move, so instrument don't need to be calibrated again. If you need to calibrate, six month or one year is ok.

 

3.We use the National standard sample in the calibration, you can test it according to the  process of common sample, if the error of test result of standard sample is within 1%, the instrument is normal. And we will provide  some sample to you.

 

4. Now most of our clients are shool,University.

 For 2005B, we have clients in Italy, Bulgaria, Poland, Russia.

 For 2001, we only have client in Ukraine.

 

Can we make a test on our product and keep a bigger portion of it for future calibration ? Or is it a special product ? I expect it is a powder ?

Do we have to make calibration after transport to Denmark ?

 

We are considering your and other systems.

I am a little worried that I have to calibrate after transport.

I look at an other where it is not necessary and the write:

 

“All major optical assemblies such as laser, cell holder and detection system are firmly fixed on one cast steel optical bench.”

 

How is your software compare to others and Malvern as well ?

1)If your budget is more than 7000USD, I still recommend LDY2005B for you. 

Our software use unconstrained free fitting analysis patent technology, directly and accurately calculate the particle size distribution by light intensity.

So this method will get more realistic and reliable particle size distribution data, are more valuable for R & D.

Compare to other factories of China, They will choose one analysis model after customer descriptions, this method will result in big error. 

Compare to malvern, malvern use their own software, and our test result is near them. 

Tsinghua University, Beijing Institute also use this kind of machine from our company,  as well as the Space Research of Beijing Institute .

our company's equipment is oldest in this industry. The data test is the most stable.

If you still has questions, you can send samples to us, we can give you a free test.

 

2) If you budget is less than 7000USD, I recommend LDY2001 for you .

Our software is very powerful. The operation is much more convenient than Malvern

The software display template is also DIY. Such as Hunan Eyre, Shenzhen Kejian, Xiamen Qunlong these dealers are selling our equipment,

And this LDY2001, we could promise  an unconditional return within one month. However, if you need to return ,the shipping freight is borne by buyers.